Printedon 100% recycled paper with soy ink. Daikin's HRV (Heat Reclaim Ventilation) recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy.
DaikinHeat reclaim Ventilator Systems(HRV) Daikin VAM-GJVE series are compact, energy-efficient and can be operated under a wide outdoor operating temperature range. The system units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, improved external static pressures offer greater design flexibility to your air
Allcontent is copyrighted by Daikin Europe N.V. VKM-GBM/GB Heat reclaim ventilation, air processing and humidification Heat reclaim ventilation and air processing Ventilation VKM-GBM/VKM-GB 50GBM 80GBM 100GBM 50GB 80GB 100GB Power input - 50Hz Heat exchange mode Nom. Ultra high kW 0.270 0.330 0.410 0.270 0.330 0.410
Daikinfresh air portfolio. All of our ventilation units offer heat recovery as a standard feature and can recover up to 81% of outgoing heat. We offer a wide range of solutions to cover almost any application, starting from as low as 10 m3/h up to 140,000 m3/h.
. Available in Capacities Refrigerant Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. Download Brochure Engineering Data All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Contact a Daikin Sales Engineer A Daikin Sales Engineer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business. AAF offers a comprehensive air filtration portfolio to provide clean air solutions for commercial and industrial applications.
Air Treatment Equipment CEK HARGA=> KATALOGUE=> SPESIFIKASI=> Heat Reclaim Ventilator — VAM series Model Names VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Improved Enthalpy Efficiency*1 Higher External Static Pressure*2 Enhanced Energy Saving Functions Seri VAM ini memberikan efisiensi entalpi yang lebih tinggi*1, karena kinerja elemen film tipis yang sangat ditingkatkan. Selain itu, tekanan statis eksternal yang ditingkatkan*2 menawarkan lebih banyak fleksibilitas untuk pemasangan. Seiring dengan ketiga peningkatan luar biasa ini, operasi pendinginan malam hari gratis berkontribusi pada konservasi energi dan lingkungan yang lebih nyaman.
Daikin Advantage Improved Air Quality A steady inflow of fresh, conditioned air improves air quality of indoor settings. Energy Efficiency Energy recovery between supply air and exhaust air eliminates waste to realize efficient ventilation. Flexible Installation Daikin’s unique modular system enables each unit to be tailor-fitted to the exact dimensions required. Product Lineup Refreshes stale indoor air with fresh outdoor air. Processes outdoor air to bring it near temperature of indoor air and distributes the air throughout the room. Indoor humidity is appropriately controlled by humidification and/or dehumidification. Outdoor-Air Processing Unit Supplying outdoor air at the same temperature of the room maintains comfort and lessens heat load caused by ventilation. * Can be connected only to VRV Heat Reclaim Ventilator Daikin’s unique heat exchange element realizes efficient heat exchange between supply air and exhaust air. High external static pressure enables flexible installation. Heat Reclaim Ventilator with DX-Coil A temperature adjustment function has been added to the Heat Reclaim Ventilator to better maintain comfort and lessen heat load caused by ventilation. * Can be connected only to VRV DESICA*:Heat Pump Desiccant Humidity Control Outdoor-Air Unit The DESICA permits individual control of humidity and temperature, by the hybrid DESICA element which contains a water absorption material and a heat exchanger, with lower energy consumption compared to conventional humidity control devices according to Daikin tests. * DESICA is a Daikin registered trademark in Japan. Technology Heat Exchange Element The thin film material allows only small water molecules moisture to penetrate while blocking out larger molecules such as CO2 . This eliminates waste by preventing the heat and moisture of the conditioned air from escaping outdoors and promotes efficient ventilation using less energy. Learn More Daikin's Unique Heat Pump Desiccant The heat pump desiccant integrates the heat exchanger and desiccant element to enable highly-efficient dehumidification and humidification with no need to supply or drain water. Learn More Wired Remote Controller Stylish Remote Controller Sleek stylish design DAIKIN APP for Installer simplifies the advanced settings such as field settings Useful administration / Shorter and Easier installation Stylish Remote Controller Navigation Remote Controller Operation is easy and smooth, just follow the indication on the remote controller Weekly schedule can be set 5 actions per day for each day of the week Circulation airflow, a function for the latest cassette type can be set Simplified Remote Controller Simple operation by using only six buttons, and users have direct access to basic functions Intuitive design by using pictograms enables user-friendly interface Overseas guests at hotels understand functions without having to know a foreign languages Case Study Case Study Visit the Daikin Global Case Studies page for detailed examples of installations Learn More After Sales Service A global support system delivers timely solutions to all needs. Learn More Preventive Maintenance Service AVAILABILITY The products or features on this page may not be available in your region. Please visit your local website for details on the products and features available in your region.
Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.
daikin heat reclaim ventilator